Form AO1-333 "Iast Concrete Plant Technician Report" - Rhode Island

What Is Form AO1-333?

This is a legal form that was released by the Rhode Island Department of Transportation - a government authority operating within Rhode Island. As of today, no separate filing guidelines for the form are provided by the issuing department.

Form Details:

  • Released on April 25, 2016;
  • The latest edition provided by the Rhode Island Department of Transportation;
  • Easy to use and ready to print;
  • Quick to customize;
  • Compatible with most PDF-viewing applications;
  • Fill out the form in our online filing application.

Download a printable version of Form AO1-333 by clicking the link below or browse more documents and templates provided by the Rhode Island Department of Transportation.

ADVERTISEMENT
ADVERTISEMENT

Download Form AO1-333 "Iast Concrete Plant Technician Report" - Rhode Island

Download PDF

Fill PDF online

Rate (4.3 / 5) 13 votes
File #:
RHODE ISLAND DEPARTMENT OF TRANSPORTATION
MATERIALS AND QUALITY ASSURANCE
IAST: CONCRETE PLANT TECHNICIAN REPORT
Acceptance Tech
Date:
Plant / Location:
Mix Type:
Concrete Tests Performed
Obtaining Sample
Gradation
Splitting Sample
Slump Test (Tol. ± 0.75")
Moisture Content
Air Content (Tol. ± 0.50%)
Yes / No
All Equipment is calibrated and in good condition?
Coarse Aggregate Gradation
Course Aggregate Producer:
2"
1 1/2"
1"
3/4"
1/2"
3/8"
# 4
# 8
# 16
Aggregate 1:
Acceptance
IAST
Variation
Within Variation
Test procedure followed?
Yes / No
C.A. Splitting Method: #Name?
2"
1 1/2"
1"
3/4"
1/2"
3/8"
# 4
# 8
# 16
Aggregate 2:
Acceptance
Independent
Variation
Within Variation
Test procedure followed?
Yes / No
Fine Aggregate Gradation
Fine Aggregate Producer:
Sive Size:
3/8"
# 4
# 8
# 16
# 30
# 50
# 100
FM
Acceptance
Independent
Variation
Within Variation
Test procedure followed?
Yes / No
F.A. Splitting Method:
Slump/Spread
Air Content (%)
Unit Wt
Thermometer
28-Day Strength (psi)
Concrete Tests
3
Avg.
(in.)
(lb/ft )
/ Heat Gun
Acceptance
#Name? #Name? #Name?
#Name?
Independent
#Name? #Name? #Name?
#Name?
Variation
#Name?
N/A
Within Variation
Test procedure followed?
Yes / No
Cylinders Fabricated:
Remarks:
All Results within Variation Limit
Resample Required
This is a Resample of File No
IAST Technician
Date
Reviewed By
Date
(Print / Sign)
(Print / Sign)
ID# AO1 - 333
REV. 4/25/16
File #:
RHODE ISLAND DEPARTMENT OF TRANSPORTATION
MATERIALS AND QUALITY ASSURANCE
IAST: CONCRETE PLANT TECHNICIAN REPORT
Acceptance Tech
Date:
Plant / Location:
Mix Type:
Concrete Tests Performed
Obtaining Sample
Gradation
Splitting Sample
Slump Test (Tol. ± 0.75")
Moisture Content
Air Content (Tol. ± 0.50%)
Yes / No
All Equipment is calibrated and in good condition?
Coarse Aggregate Gradation
Course Aggregate Producer:
2"
1 1/2"
1"
3/4"
1/2"
3/8"
# 4
# 8
# 16
Aggregate 1:
Acceptance
IAST
Variation
Within Variation
Test procedure followed?
Yes / No
C.A. Splitting Method: #Name?
2"
1 1/2"
1"
3/4"
1/2"
3/8"
# 4
# 8
# 16
Aggregate 2:
Acceptance
Independent
Variation
Within Variation
Test procedure followed?
Yes / No
Fine Aggregate Gradation
Fine Aggregate Producer:
Sive Size:
3/8"
# 4
# 8
# 16
# 30
# 50
# 100
FM
Acceptance
Independent
Variation
Within Variation
Test procedure followed?
Yes / No
F.A. Splitting Method:
Slump/Spread
Air Content (%)
Unit Wt
Thermometer
28-Day Strength (psi)
Concrete Tests
3
Avg.
(in.)
(lb/ft )
/ Heat Gun
Acceptance
#Name? #Name? #Name?
#Name?
Independent
#Name? #Name? #Name?
#Name?
Variation
#Name?
N/A
Within Variation
Test procedure followed?
Yes / No
Cylinders Fabricated:
Remarks:
All Results within Variation Limit
Resample Required
This is a Resample of File No
IAST Technician
Date
Reviewed By
Date
(Print / Sign)
(Print / Sign)
ID# AO1 - 333
REV. 4/25/16