Form LW203B "Onsite Liquid Waste Photo Inspection Form" - New Mexico

What Is Form LW203B?

This is a legal form that was released by the New Mexico Environment Department - a government authority operating within New Mexico. As of today, no separate filing guidelines for the form are provided by the issuing department.

Form Details:

  • Released on April 16, 2020;
  • The latest edition provided by the New Mexico Environment Department;
  • Easy to use and ready to print;
  • Quick to customize;
  • Compatible with most PDF-viewing applications;
  • Fill out the form in our online filing application.

Download a fillable version of Form LW203B by clicking the link below or browse more documents and templates provided by the New Mexico Environment Department.

ADVERTISEMENT
ADVERTISEMENT

Download Form LW203B "Onsite Liquid Waste Photo Inspection Form" - New Mexico

408 times
Rate (4.6 / 5) 21 votes
NEW MEXICO ENVIRONMENT DEPARTMENT
Environmental Health Bureau
Onsite Liquid Waste Photo Inspection Form
Applicant Name:
System Address (Street, City):
NMED LW Permit No.
☐ Photo Inspection
☐ Initial Inspection
☐ Re-inspection
☐ Final Inspection
☐ New
Item #
* See Guidance Policy
☐ Mod
☐ Other:
any mod requires effluent filter & access risers installed
Building Sewer to Septic Tank 504
In
Out
N/A
N/O
1.
1.1.
Correct size and material: 4” SCH 40, PVC Foam Core or ABS (UPC allows 3” structure stub out, 4” min required for tank inlet & tee) 502E
1.2.
Cleanouts: Required cleanouts present, Installed correctly, to grade, for each 100 feet or fraction thereof. Installed pursuant to NMPC 504B
Bedding and Slope: Pipe properly bedded on compact or native soil, correct slope 2% min
, or 1% min
where 2%
(1/4” per foot)
(1/8” per foot)
1.3.
impractical & 4” or larger pipe 504A
Septic Tank 501, 502
In
Out
N/A
N/O
2.
☐ Concrete
☐ Plastic / Fiberglass
(IAPMO/ANSI Z1000-2013, ASTM C1227-13)
2.1.
Matches Application: the number, tank size and type match the application Table 201.2,502C
2.2.
Setback- tank(s) meet(s) all setback requirements including, structures, neighboring wells, water courses, water bodies Table 302.1
Tank Location:
Latitude:
Longitude:
Elevation:
2.3.
Located as per site plan
Latitude
Longitude:
Elevation
2.4.
Onsite Well Location:
Latitude
Longitude:
Elevation
2.5.
Offsite Well Location:
Labeled: Tank is approved & correctly labeled (Concrete tanks marked with manufacturer's name, New Mexico certification number, year of
2.6.
construction & tank capacity in gallons permanently displayed on the tank above the outlet pipe 501B-4
2.7.
Level, Orientation & Cover: Tank level, correctly oriented, does not exceed 3‘ max cover (unless approved for >3’) tank 501J-7,501B-2,501H
2.8.
Inlet/Outlet pipes: are sealed and watertight; correct size, material, poly-boot installed on outlet, 502E,* Guidance
2.9.
Inlet/Outlet Baffle or Tee: extends 12” minimum below and 4” above liquid level 502F
2.10.
Venting: Tank and fittings correctly vented (tank has 2” min back vent opening, 9” min air space above liquid, baffle wall vent area) 502G,502I
2.11.
Effluent filter: Installed vertical orientation with handle (solid material) extending to within 6” of the riser cover 502H
2.12.
Manholes: (2) correctly sized 20” min & located above inlet and outlet tee. Tanks over 12’ long require a third manhole opening.502D
2.13.
Risers: at grade, secure lids (58# or fasteners), depth/correct diameter (0-3’/24”min; >3’/30”min) 501E,502D, watertight sealed to tank 501B10
2.14.
Concrete Tank Coating: coated with bituminous material to 6” below water line, OR approved material OR Type V Concrete 501J-5
Plastic Tank: Installed per Manufacturer’s instructions (instructions available on-site) (marked with manufacturer's name, model number, code or
2.15.
date of manufacture, tank capacity in gallons, max cover, inlet and outlet permanently displayed on the tank) 501I
2.16.
Water-tightness: test conducted (required for all holding tanks) and determined watertight 203D,501B-5
2.17.
Flotation Prevention: properly installed for tanks in high groundwater or floodplains 501B7 * Guidance
Pumps and Pump Tanks 503 Holding Tanks 808 approved material, concrete, plastic, fiberglass designed & constructed for purpose, meets
3.
In
Out
N/A
N/O
structural requirements of septic tanks
Type & Size: Pump size and type matches application; designed to pump sewage, or effluent, Single pump up to 1000gpd, dual alternating
3.1.
pumps over 1000gpd 807A-6; sized for intended purpose 503D, holding tank 1000gal min or 4 times design flow whichever greater
3.2.
Water-tightness: test conducted pump tank (at dept discretion), (req’d for holding tanks) determined to be watertight 203D,501B-5,503A
3.3.
Concrete Tanks: If concrete, coated to protect corrosion or approved additive or Type V Concrete 501J-5,503A Circle: Plastic / Fiberglass
3.4.
Accessible: Valves, motors, pumps, aerators etc. are accessible for inspection and repair; Access port minimum of 20” 503B
3.5.
Covers: shall have locking mechanism or if concrete, be min. 58 pounds 501E,503B
Alarms: Equipped with both audible and visible alarms, or remote and visual alarms, for high water & pump failure; conspicuous location;
3.6.
contained in weather-proof structure; All alarm & control circuits are on a separate circuit from pumps 503C
3.7.
Siphoning/Freezing: Provisions made for the prevention of siphoning back to the pump tank and prevention of freezing 503D * Guidance
In
Out
N/A
N/O
4.
Distribution Box
Tee
Drop Box
701
4.1.
concrete footing 701H
Installed on a level base in
natural undisturbed or
compacted soil or on a
4.2.
Distribution Box / Tee min 5’ setback from nearest point of disposal field product Table 302.1
4.3.
Concrete D-Boxes: coated with bituminous coating or other approved material 701H-1
Connections between septic tank and distribution box SDR 35 or better pipe with watertight joints on natural ground or compacted fill or
4.4.
appropriate bedding material.701H-3
Access Riser: provided to ground surface for each distribution box. 701H * Guidance
4.5.
LW 203B Onsite LW Photo Inspection Form FR 200416
page ________ of __________pages
NEW MEXICO ENVIRONMENT DEPARTMENT
Environmental Health Bureau
Onsite Liquid Waste Photo Inspection Form
Applicant Name:
System Address (Street, City):
NMED LW Permit No.
☐ Photo Inspection
☐ Initial Inspection
☐ Re-inspection
☐ Final Inspection
☐ New
Item #
* See Guidance Policy
☐ Mod
☐ Other:
any mod requires effluent filter & access risers installed
Building Sewer to Septic Tank 504
In
Out
N/A
N/O
1.
1.1.
Correct size and material: 4” SCH 40, PVC Foam Core or ABS (UPC allows 3” structure stub out, 4” min required for tank inlet & tee) 502E
1.2.
Cleanouts: Required cleanouts present, Installed correctly, to grade, for each 100 feet or fraction thereof. Installed pursuant to NMPC 504B
Bedding and Slope: Pipe properly bedded on compact or native soil, correct slope 2% min
, or 1% min
where 2%
(1/4” per foot)
(1/8” per foot)
1.3.
impractical & 4” or larger pipe 504A
Septic Tank 501, 502
In
Out
N/A
N/O
2.
☐ Concrete
☐ Plastic / Fiberglass
(IAPMO/ANSI Z1000-2013, ASTM C1227-13)
2.1.
Matches Application: the number, tank size and type match the application Table 201.2,502C
2.2.
Setback- tank(s) meet(s) all setback requirements including, structures, neighboring wells, water courses, water bodies Table 302.1
Tank Location:
Latitude:
Longitude:
Elevation:
2.3.
Located as per site plan
Latitude
Longitude:
Elevation
2.4.
Onsite Well Location:
Latitude
Longitude:
Elevation
2.5.
Offsite Well Location:
Labeled: Tank is approved & correctly labeled (Concrete tanks marked with manufacturer's name, New Mexico certification number, year of
2.6.
construction & tank capacity in gallons permanently displayed on the tank above the outlet pipe 501B-4
2.7.
Level, Orientation & Cover: Tank level, correctly oriented, does not exceed 3‘ max cover (unless approved for >3’) tank 501J-7,501B-2,501H
2.8.
Inlet/Outlet pipes: are sealed and watertight; correct size, material, poly-boot installed on outlet, 502E,* Guidance
2.9.
Inlet/Outlet Baffle or Tee: extends 12” minimum below and 4” above liquid level 502F
2.10.
Venting: Tank and fittings correctly vented (tank has 2” min back vent opening, 9” min air space above liquid, baffle wall vent area) 502G,502I
2.11.
Effluent filter: Installed vertical orientation with handle (solid material) extending to within 6” of the riser cover 502H
2.12.
Manholes: (2) correctly sized 20” min & located above inlet and outlet tee. Tanks over 12’ long require a third manhole opening.502D
2.13.
Risers: at grade, secure lids (58# or fasteners), depth/correct diameter (0-3’/24”min; >3’/30”min) 501E,502D, watertight sealed to tank 501B10
2.14.
Concrete Tank Coating: coated with bituminous material to 6” below water line, OR approved material OR Type V Concrete 501J-5
Plastic Tank: Installed per Manufacturer’s instructions (instructions available on-site) (marked with manufacturer's name, model number, code or
2.15.
date of manufacture, tank capacity in gallons, max cover, inlet and outlet permanently displayed on the tank) 501I
2.16.
Water-tightness: test conducted (required for all holding tanks) and determined watertight 203D,501B-5
2.17.
Flotation Prevention: properly installed for tanks in high groundwater or floodplains 501B7 * Guidance
Pumps and Pump Tanks 503 Holding Tanks 808 approved material, concrete, plastic, fiberglass designed & constructed for purpose, meets
3.
In
Out
N/A
N/O
structural requirements of septic tanks
Type & Size: Pump size and type matches application; designed to pump sewage, or effluent, Single pump up to 1000gpd, dual alternating
3.1.
pumps over 1000gpd 807A-6; sized for intended purpose 503D, holding tank 1000gal min or 4 times design flow whichever greater
3.2.
Water-tightness: test conducted pump tank (at dept discretion), (req’d for holding tanks) determined to be watertight 203D,501B-5,503A
3.3.
Concrete Tanks: If concrete, coated to protect corrosion or approved additive or Type V Concrete 501J-5,503A Circle: Plastic / Fiberglass
3.4.
Accessible: Valves, motors, pumps, aerators etc. are accessible for inspection and repair; Access port minimum of 20” 503B
3.5.
Covers: shall have locking mechanism or if concrete, be min. 58 pounds 501E,503B
Alarms: Equipped with both audible and visible alarms, or remote and visual alarms, for high water & pump failure; conspicuous location;
3.6.
contained in weather-proof structure; All alarm & control circuits are on a separate circuit from pumps 503C
3.7.
Siphoning/Freezing: Provisions made for the prevention of siphoning back to the pump tank and prevention of freezing 503D * Guidance
In
Out
N/A
N/O
4.
Distribution Box
Tee
Drop Box
701
4.1.
concrete footing 701H
Installed on a level base in
natural undisturbed or
compacted soil or on a
4.2.
Distribution Box / Tee min 5’ setback from nearest point of disposal field product Table 302.1
4.3.
Concrete D-Boxes: coated with bituminous coating or other approved material 701H-1
Connections between septic tank and distribution box SDR 35 or better pipe with watertight joints on natural ground or compacted fill or
4.4.
appropriate bedding material.701H-3
Access Riser: provided to ground surface for each distribution box. 701H * Guidance
4.5.
LW 203B Onsite LW Photo Inspection Form FR 200416
page ________ of __________pages
NMED LW Permit No.
Convention Disposal System 703 Soil Treatment Area, shall not be: subject to any vehicular
5.
In
Out
N/A
N/O
traffic, paved over or covered by any material that reduce or inhibit evaporation.
Soil- Soil Type below trench bottom verified, most restrictive layer; AR matches soil type on application; in place natural soil <30% gravel
5.1.
Table 703.1,703E,703I Soil Type
Type Ia
Type Ib
Type II
Type III
Type IV
5.2.
Soil- Smeared Soils Not Present on Trench or Sidewalls, rake 1” deep; Soil not compacted in soil treatment area 701D
5.3.
Setback- Correct Clearance to Ground Water or Limiting layer 303B
5.4.
Setback- Disposal system meets all setback requirements including neighbor’s wells, water courses, water bodies Table 302.1
5.5.
Trench-Pipe and Gravel: trench length, width, depth of gravel below pipe, number of trenches & trench spacing matches application 701E,701K
Linear Feet Total:
Width:
Depth below pipe:
Gravel above pipe:
5.6.
Trench Dimensions:
Trench-Pipe and Gravel: Aggregate ¾” to 2 ½”, clean washed rock or crushed gravel 7A-4
5.7.
Aggregate receipt attached for (cubic yards)__________________; amount meets or exceeds permitted plan
5.8.
Trench-Pipe and Gravel: Correct Pipe; 2-hole 30° to 60° from invert,4" Minimum Diameter, End Caps, 701C,701D,701J
5.9.
Trench-Pipe and Gravel: Pipe covered with 2” min aggregate and with Approved Material 701D
5.10.
Trench-Pipe and Gravel: Pipe Covered with Geotextile Fabric instead of Aggregate 701D
5.11.
Trench- Chamber- Type, number of units & spacing matches application; meets manufacturers specs 701E; No. of Units ________________
5.12.
Trench-Synthetic Aggregate- Type, number of units, configuration & spacing matches application; meets manufacturers specs 701E
5.13.
Trench- Other Approved Products- Type, number of units, configuration & spacing matches application; meets manufacturer specs 701E
5.14.
Inspection Port- Inspection Port(s), Capped SDR35 or better 701F
5.15.
Stepped Systems: watertight joints on undisturbed ground 701L
5.16.
Soil Replacement- Type 1b soil required; Replacement soil at least 48” deep below trench bottom 701M
5.17.
Soil Replacement- Replacement soil at least 24” width around sides and ends of trench 701M
5.18.
Absorption Bed- at least 6” aggregate below invert of distribution pipe; Up to additional 1 ft of aggregate allowed 701B
5.19.
Absorption Bed- properly sized bed is 1.5 X AR for conventional trenches; calculate using total bottom and sidewall area below pipe 703K
5.20.
Seepage Pit- Meets all material, sizing and installation requirements in Section 702 and 703A,703L
5.21.
Seepage Pit- 6” of Bentonite clay or approved material installed at bottom of pit 702K
6.
Advanced Treatment Systems and Alternative Disposal Systems (ATS/ADS) (NMED Only)
In
Out
N/A
N/O
6.1.
For any system that includes an ATS and/or an ADS, the ATS/ADS Inspection Form must be completed in addition to this inspection form
Continued on attached sheet(s)
As Built attached (required when deviating from plan
Photos attached
Photos Submitted (electronic)
)
Installer Comments
I certify that this liquid waste system was installed in accordance with the permit approved by NMED, unless otherwise noted in Comments Section above.
Installer Printed Name:
Installer’s Signature:
Date:
NMED Use Only
Comments / Conditions:
Installation Approved
Installation Not Approved
Corrective Action Response required
Re-Inspection required
NMED Inspector Printed Name:
NMED Inspector’s Signature:
Date:
LW 203B Onsite LW Photo Inspection Form FR 200416
page ________ of __________pages